That is in the schematic with one battery bank situation with a solar panel the wires were attached one way.
The other schematic with the two battery bank and engine alternator hooked up it shows the
reversed.
So is that because the second schematic has two batteries or
because the second schematic has a alternator hooked up?
We called Xantrex support :
541 Roske Drive, Suite A
Elkhart, Indiana
USA 46516
1-800-446-6180
Xantrex support said it was
mis-print. A possible photo copy error.
It would be as easy
as looking at the amp hr to determine if they need correcting.
If the amp hours are counting back to zero from a negative (-)
while charging the batteries then all is OK.
If not then reverse the yellow and brown twisted pair on the
shunt where they are connected. Just connect the yellow to where the brown is
and the brown to where the yellow was.
Xantrax support was nice and took their time explaing this setup.
OK that was, well confusing and time consuming but we have an
answer!
Thank you! You have solved a problem that I have had for seven years.