Lightning ground wire to - found

"Lightning Grounds
Connect a 4 AWG battery cable from the base of your aluminum mast to the nearest keel bolt from external ballast.  If you have internal ballast, you should install a lightning ground plate. One square foot is recommended for use in salt water; fresh water requires much more. Do not rely on a thru-hull or a sintered bronze radio ground (e.g. Dynaplate) for use as a lightning ground.


For additional comfort, also run a 6 AWG wire from your keel bolt or ground plate to the upper shroud chainplates, and to your headstay chainplate. Don't bother with the backstay if it is interrupted with antenna insulators. Have each of the cables that are used for lightning ground wires lead as directly as possible to the same keel bolt, with any necessary bends being smooth and gradual."


OK now for the plate?


grounds.htm

No comments:

Post a Comment